{"slug":"emt-2285-1-4-ft","name":"EMT 2285-1-4-FT","family":"EMT","family_name":"EMT","locale":"en","url":"https://heatpumps.energymachines.com/products/emt-2285-1-4-ft","refrigerant":"R1234ze","compressor_type":"Turbo","specifications":[{"key":"application","value":["cooling","DHW","heating"],"unit":null,"quantity_type":null},{"key":"capacity_control","value":"Frequency controlled","unit":null,"quantity_type":null},{"key":"certification","value":"CE","unit":null,"quantity_type":null},{"key":"commissioned_weight","value":4000,"unit":"kg","quantity_type":"mass","canonical_value":4000,"canonical_unit":"kg","conversion_available":true},{"key":"compressor_type","value":"Turbo","unit":null,"quantity_type":null},{"key":"energy_source","value":["ground","waste heat","water"],"unit":null,"quantity_type":null},{"key":"gwp","value":1.37,"unit":null,"quantity_type":null,"canonical_value":1.37,"canonical_unit":null,"conversion_available":false},{"key":"h","value":2140,"unit":"mm","quantity_type":"length","canonical_value":2140,"canonical_unit":"mm","conversion_available":true},{"key":"high_condenser_outlet_temp","value":65,"unit":"C","quantity_type":"temperature","canonical_value":65,"canonical_unit":"c","conversion_available":true},{"key":"highest_evaporator_outlet_temp","value":27,"unit":"C","quantity_type":"temperature","canonical_value":27,"canonical_unit":"c","conversion_available":true},{"key":"highest_heating_temperature_at_lowest_source","value":35,"unit":"C","quantity_type":"temperature","canonical_value":35,"canonical_unit":"c","conversion_available":true},{"key":"l","value":3040,"unit":"mm","quantity_type":"length","canonical_value":3040,"canonical_unit":"mm","conversion_available":true},{"key":"lowest_evaporator_temp_to_reach_highest_condenser_temp","value":7,"unit":"C","quantity_type":"temperature","canonical_value":7,"canonical_unit":"c","conversion_available":true},{"key":"lowest_inlet_temperature","value":-12,"unit":"C","quantity_type":"temperature","canonical_value":-12,"canonical_unit":"c","conversion_available":true},{"key":"nominal_cooling","value":551,"unit":"kW","quantity_type":null,"canonical_value":551,"canonical_unit":"kW","conversion_available":false},{"key":"nominal_cooling_cop","value":3.44,"unit":null,"quantity_type":null,"canonical_value":3.44,"canonical_unit":null,"conversion_available":false},{"key":"nominal_cop_heating","value":3.68,"unit":null,"quantity_type":null,"canonical_value":3.68,"canonical_unit":null,"conversion_available":false},{"key":"nominal_heat","value":694,"unit":"kW","quantity_type":null,"canonical_value":694,"canonical_unit":"kW","conversion_available":false},{"key":"refrigerant","value":"R1234ze","unit":null,"quantity_type":null},{"key":"safety_class","value":"A2L","unit":null,"quantity_type":null},{"key":"special_features","value":["economizer","oil-free"],"unit":null,"quantity_type":null},{"key":"use_case","value":"commercial building","unit":null,"quantity_type":null},{"key":"w","value":1290,"unit":"mm","quantity_type":"length","canonical_value":1290,"canonical_unit":"mm","conversion_available":true}],"excerpt":null,"body":"This Energy Machines™ EMT model contains two oil-free centrifugal compressors in one refrigerant circuit. The compressor is classified as a non-positive displacement compressor.\r\n\r\n\r\n\r\n\r\n\r\nThis model is equipped with a flash tank, increasing its energy efficiency. The machine’s evaporator and condenser are shell-and-tube heat exchangers. The evaporator operates with a flooded evaporation technique.\r\n\r\n\r\n\r\n\r\n\r\nThese components work together to create a powerful and efficient machine.","measurement_system":"metric","media":[{"url":"https://heatpumps.energymachines.com/uploads/frame-G_pos1_25110501.jpg","alt":"frame-G_pos1_25110501.jpg","role":"gallery"}],"shared_content":{"software":"**EM Control**\r\n*Seamless control and automation*\r\nAll Energy Machines heat pumps are equipped with Energy Machines' control system package, EM Control. EM Control includes on-site hardware and embedded software for monitoring, controlling, and automating buildings and industrial processes. These capabilities are augmented by EM Cloud for full remote management.\r\n\r\n**EM Cloud**\r\n*Flexible optimization from anywhere*\r\nThe EM Control package includes EM Cloud, a cloud-based visual energy system management platform. Featuring SCADA/HMI software, EM Cloud offers cloud-based visualization of control system data and performance. Users can collect real-time building energy data, command PLCs or other devices, and control elements in order to adapt their heat pump or energy system to meet evolving needs while ensuring energy is never wasted. Continuous monitoring and storage provide insights for optimization, with full remote management.\r\n\r\n*(Optional add-on)*\r\n**EM Verify**\r\n*Transparent heat pump performance*\r\nEM Verify, an optional add-on within EM Cloud, provides real-time monitoring of heat pump performance. Metrics include heat pump efficiency (COP), compressor COP, energy production, cycle efficiency, and an early warning system for predictive maintenance. By demystifying heat pump operations, EM Verify enables users to make informed decisions for optimal efficiency and cost savings.","supplementary":"**EMHW**\r\nEMHW products are designed for production of warm tap water with serial connected heat exchangers. The heat exchangers heat water (or liquid) in stages up to 60°C (140°F). The heat exchangers can utilize different heat sources.\r\n\r\nThe EMHW is a cohesive unit, where all exchanger pumps and valves are pre-connected and tested before leaving the factory. The machine is delivered factory-finished, only requiring on-site connection to pipework and electricity. Equipped with control valves and circulation pumps, the unit integrates into an energy system to fulfill the required temperature levels.\r\n\r\nRefrigerant: EMHW does not contain refrigerant circuits.\r\n\r\nNominal heating capacity: 130-500 kW\r\n\r\n**EMCW**\r\nEMCW products are similar to EMHW products, but designed for cooling water or liquids.\r\n\r\nThe EMCW is a cohesive unit, where all exchanger pumps and valves are pre-connected and tested before leaving the factory. The machine is delivered factory-finished, only requiring on-site connection to pipework and electricity. Equipped with control valves and circulation pumps, the unit integrates into an energy system to fulfill the required temperature levels.\r\n\r\nRefrigerant: EMCW does not contain refrigerant circuits.\r\n\r\nNominal cooling capacity: Defined by request"},"documents":[{"document_id":"cmw3peajr00slzqmeksv4nh9g","product_slug":"emt-2285-1-4-ft","product_name":"EMT 2285-1-4-FT","label":"Datasheet EMT-2285-1-4(7)-FT-AC V2.0, Apr 2026.pdf","doc_type":"attachment","mime_type":"application/pdf","url":"https://heatpumps.energymachines.com/uploads/Datasheet_EMT-2285-1-4_7_-FT-AC_V2.0__Apr_2026.pdf"}],"note":"Nominal values and individual temperature limits are screening data, not performance guarantees at your operating point. Confirm simultaneous source/supply conditions, duty, flow, fluid and redundancy with Energy Machines."}